[Did You Know About Cooling?] How to Maintain a DC Fan?


Category:

News Center

Industry Trends

Release time:

2019-06-12

When using DC cooling fans, have you ever encountered a situation where they fail shortly after starting up? DC fan Like other machinery and equipment, we need to regularly maintain and inspect it to identify any potential issues—this will help extend its service life. The following are maintenance methods and storage conditions for cooling fans:
1. During operation, if the DC cooling fan exhibits any of the following abnormalities—unusual noises, severe motor overheating, live casing, tripped circuit breaker, or failure to start—it should be immediately shut down and inspected. To ensure safety, repairs are not permitted while the fan is running. After maintenance, a trial run of approximately 5 to 10 minutes is required to confirm that no abnormalities remain before resuming normal operation.
2. The fan may only be operated when it is completely normal and functioning properly. At the same time, ensure that the power supply has sufficient capacity and stable voltage. It is strictly prohibited to operate the fan beyond or below its specified voltage range, or to run it with a phase missing. The power supply line must be dedicated; long-term use of temporary lines for power supply is not permitted.
3. The operating environment for DC fans should be kept regularly well-ventilated, dry, and clean. The fan surface must be kept clean, and the air inlets and outlets should be free of any debris. Dust and other foreign objects inside the fan and ducts should be removed periodically.
4. According to the operating environment, periodically replenish or replace the lubricant in the bearings (for enclosed motor bearings, lubricant does not need to be replaced throughout the bearing’s service life). To ensure proper lubrication of the DC cooling fan during operation, lubricate the enclosed bearings and motor bearings at least once every 1,000 hours. Use ZL-3 lithium-based grease to fill one-third of both the inner and outer races of the bearings. Running with insufficient lubrication is strictly prohibited.
5. DC cooling fans should be stored in a dry environment to prevent the motor or drive unit from getting damp. When storing DC cooling fans outdoors, appropriate protective measures must be taken. During storage and handling, care should be taken to avoid bumps or strong impacts from external forces, so as to prevent damage to the fan.
Shenzhen Jiangshanlai Electronic Technology Co., Ltd. was founded in 2005 in Shenzhen, China. It is a large-scale enterprise integrating customization, R&D, manufacturing, sales, and service of DC brushless motors, DC cooling fans, cooling fans, DC brushless fans, DC stand-mounted fans, boosted cooling fans, miniature cooling fans, DC cooling fans, DC blowers, and non-standard fans. We are a wholesale manufacturer and supplier of DC fans. Our products are best-selling in Guangdong Province—including Shenzhen, Guangzhou, and Dongguan—as well as in Fujian, Zhejiang, and Jiangsu provinces.
 

Previous: [Did You Know About Cooling?] How are cooling fans designed?

Next: [Did You Know About Cooling?] Why do cooling fans fail?

Related News

Company dinner

On these busy days, I’m grateful to have you all fighting side by side! At this company dinner, everyone can put aside their daily hustle and enjoy some wonderful moments together. Let’s raise our glasses and chat freely—may delicious food and laughter accompany us as we strengthen our team spirit and build an even warmer sense of unity!

2025-08-27

Weekend team-building event

The weekend team-building event by the seaside came to a perfect close! With sunny beaches and endless laughter, the team collaborated seamlessly in fun-filled games, relaxing their minds and bodies amid the soothing sound of ocean waves. Filled with renewed energy, we’re ready to join hands and tackle new challenges together!

2025-08-25

Display cabinet

The newly installed display cabinets at the Huizhou company are gradually being filled up...

2025-08-21

Jiangshan Lai Electronics wishes you a happy Mid-Autumn Festival 2022!

On a day of blooming flowers and a full moon, When families are reunited in joy, May our land send you warm wishes for a happy Mid-Autumn Festival!

2022-09-10

Jiangshan wishes you a healthy and happy Dragon Boat Festival 2022!

The fragrant aroma of zong leaves fills the air on May 5th— May our heartfelt wishes bring you peace and well-being this Dragon Boat Festival! May our land send its best wishes for your health and happiness this Dragon Boat Festival 2022!

2022-06-03

May the land and rivers bring you joy as we celebrate Labor Day!

Salute to the workers! May our country and its people bring joy and happiness to all our customers and employees on this special occasion!

2022-05-01

Advantages and Applications of Oil-Bearing DC Fans

The pivot joint is fixed at the position of the motor stator base, ensuring an appropriate gap between the rotor and the stator. Of course, there must also be a clearance between the shaft core and the bearings to prevent the shaft core from becoming locked and thus unable to function. The stator structure of the motor—hereafter referred to as the "stator"—is designed in such a way that, once power is supplied, an induced magnetic field will be generated between the rotor and the stator. The control circuit then drives the electric fan motor into operation. Therefore, in the conventional fan motor design, as long as the fan rotor, the motor stator, and the drive circuit work together via the pivot joint between the shaft core and the bearings and through magnetic field induction, the motor can operate effectively.

2022-04-18