A Brief Discussion on DC Blowers


Category:

Industry Trends

Release time:

2020-06-22

Blower It mainly consists of the following six components: motor, air filter, blower body, air chamber, base (which also serves as an oil tank), and oil-drip nozzle. The blower operates by means of an eccentrically mounted rotor within the cylinder; as the rotor rotates off-center, the volume between the blades in the rotor slots varies, thereby drawing in, compressing, and discharging air. During operation, the pressure differential generated by the blower automatically delivers lubricant to the oil-drip nozzle, which then drips it into the cylinder to reduce friction and noise. At the same time, this lubrication prevents backflow of gas within the cylinder. Such blowers are also known as vane-type blowers. The blower primarily handles clean air, clean gas, sulfur dioxide, and other inert gases as its working medium. Customized production is available upon request to handle other flammable, explosive, corrosive, toxic, or special gases as well.
 
Before starting the equipment, operators must familiarize themselves with these operating procedures and strictly follow them when running the blower.
 
1. Check the lubricant level in the oil tank; it should be between the upper and lower limits indicated by the dipstick.
 
2. Notify the substation to supply power to this unit.
 
3. Inspect the control cabinet on board; there should be no alarm indications. If an alarm is present, identify the cause and eliminate it.
 
4. Select the “Manual” mode. (Touch the “Manual” button with your finger.)
 
5. Check whether the relief valve is in the open position (the green light indicating the relief valve is open will be illuminated). Also, verify that the diffuser is set to its minimum opening (the green light indicating the diffuser is at its minimum opening will be illuminated).
 
6. After confirming through the above checks that the fan is ready to start, press the start button to initiate the blower’s startup procedure: ① The auxiliary oil pump will perform pre-lubrication for one minute (the green light indicating the auxiliary oil pump is running will illuminate). ② The blower can then begin operation (the green light indicating the blower is running will illuminate).
 
③ The relief valve closes slowly (the green light indicating the relief valve is open turns off, and two minutes later, the green light indicating the relief valve is closed turns on).
 
④ The auxiliary oil pump stops running (the green light indicating the auxiliary oil pump is running goes off, and the red light indicating it has stopped turns on). At this point, the blower has started up successfully and can be put into formal operation.
 
⑤ If the blower fails to start as scheduled after the start button is pressed, the red low-oil-pressure alarm light will illuminate one minute later, and the entire starting process will be halted. You must identify and resolve the cause before clearing the alarm and restarting the system.
 
1. After the fan is started, you can slowly adjust the diffuser opening according to production needs using the “Open” and “Close” buttons on the diffuser to ensure the required air volume.
 
2. During fan operation, it is essential to monitor the fan regularly, paying close attention to its current, oil temperature, oil pressure, inlet vacuum level, sound, temperature, vibration, and other relevant parameters. Keep accurate records on a regular basis. If any abnormalities are detected, promptly identify the cause and take corrective measures. Also, report the issue to the Production Department immediately. If necessary, emergency shutdown procedures may be implemented (use with caution).
 

Previous: What’s the difference between DC cooling fans and AC cooling fans?

Next: What is a DC fan? What is its working principle?

Related News

Company dinner

On these busy days, I’m grateful to have you all fighting side by side! At this company dinner, everyone can put aside their daily hustle and enjoy some wonderful moments together. Let’s raise our glasses and chat freely—may delicious food and laughter accompany us as we strengthen our team spirit and build an even warmer sense of unity!

2025-08-27

Weekend team-building event

The weekend team-building event by the seaside came to a perfect close! With sunny beaches and endless laughter, the team collaborated seamlessly in fun-filled games, relaxing their minds and bodies amid the soothing sound of ocean waves. Filled with renewed energy, we’re ready to join hands and tackle new challenges together!

2025-08-25

Display cabinet

The newly installed display cabinets at the Huizhou company are gradually being filled up...

2025-08-21

Jiangshan Lai Electronics wishes you a happy Mid-Autumn Festival 2022!

On a day of blooming flowers and a full moon, When families are reunited in joy, May our land send you warm wishes for a happy Mid-Autumn Festival!

2022-09-10

Jiangshan wishes you a healthy and happy Dragon Boat Festival 2022!

The fragrant aroma of zong leaves fills the air on May 5th— May our heartfelt wishes bring you peace and well-being this Dragon Boat Festival! May our land send its best wishes for your health and happiness this Dragon Boat Festival 2022!

2022-06-03

May the land and rivers bring you joy as we celebrate Labor Day!

Salute to the workers! May our country and its people bring joy and happiness to all our customers and employees on this special occasion!

2022-05-01

Advantages and Applications of Oil-Bearing DC Fans

The pivot joint is fixed at the position of the motor stator base, ensuring an appropriate gap between the rotor and the stator. Of course, there must also be a clearance between the shaft core and the bearings to prevent the shaft core from becoming locked and thus unable to function. The stator structure of the motor—hereafter referred to as the "stator"—is designed in such a way that, once power is supplied, an induced magnetic field will be generated between the rotor and the stator. The control circuit then drives the electric fan motor into operation. Therefore, in the conventional fan motor design, as long as the fan rotor, the motor stator, and the drive circuit work together via the pivot joint between the shaft core and the bearings and through magnetic field induction, the motor can operate effectively.

2022-04-18